Double click on OPC server and Set the StartUp option to Automatic and the Log On As: option to System Account, uncheck Allow Interaction With Desktop.
#RSLINX CLASSIC LITE OPC SOFTWARE#
#RSLINX CLASSIC LITE OPC FULL#
RDISK is not a replacement for a full back up.
#RSLINX CLASSIC LITE OPC UPDATE#
It is strongly recommended to run RDISK /S to update Windows NT repair information and create an emergency repair disk. Using the registry editors incorrectly may cause the system to become unbootable.
This article includes information about modifying the system's registry. "Server is Busy " message when rebooting the machine. Rslinx fails to start as a service and the following entries are found in the NT SYSTEM.LogĮvent ID 10010 The server did not register with DCOM within the required timeout.Įvent ID 7009 Timeout (120000 milliseconds) waiting for service to connect.Įvent ID 7000 The RSlinx service failed to start due to the following error: The service did not respond to the start or control request in a timely fashion. Multiple Application errors returned from Rslinx when logging out of NT.ĬoCreate instance failed errors when starting iFIX. Configuring it to run as a service requires additional steps to avoid the following: Range(“DDE_Sheet!C7”).RSLinx OPC server can be configured as an iFIX Data Server. RSIchan = DDEInitiate(“RSLinx”, “testsol”) This is the destination of the data that will be read by the macro. This macro assumes that there is a worksheet created and saved as RSLINX.xls and with sheet DDE_Sheet . Reading data from a PLC via DDE requires a macro like the following. Using Macros (as contained in the RS Linx Online reference): This can be done in two ways using a DDE link and using Macros.Ħ. Using direct DDE link to import data to Excel. Select a cell in Excel sheet and enter the following formula:ħ. We need to start MS Excel and tell it what the topic is and we are set. We are now ready to start a DDE communication. Then associate this topic with the PLC by clicking on the PLC name on the Data Source tab of the same window then click apply.ĥ. To do this, go to DDE/OPC>Topic Configuration. You will need to configure a topic in RSLinx. Before you proceed, check to make sure that the PLC is online. To do this, in RSLinx click on Communications>Configure Drivers>Ethernet Devices.
#RSLINX CLASSIC LITE OPC DRIVERS#
Simply go to Control Panel>Administrative Tools>Services and enable Network DDE and Network DDE DSDMĢ. Open up RSLinx and configure the drivers so that the PLC can be seen online. Enable DDE communication in the computer. Ensure that the PLC and the computer are connected to the Ethernet. Here are the steps required to achieve this goal:ġ. DDE can be used to exchange data between two programs. The data contained in the PLC resgisters can be imported to Excel using Dynamic Data Exchange (DDE). For an industrial engineer, sometimes there arises a need to import process data to a computer for manipulation.